| Test | Test Standard | Result | Conducted By |
| Sound Absorption Dry Density | ASTM C423-84A E795 ASTM E605 |
NRC .50 to 1.1 7 lb. ft. |
Riverbank Acoustical Labs |
| Sound Transmission Dry Density |
ASTM E90-85 ASTM 413-73 ASTM E605 |
Single Wall to STC 54 Double Wall to STC 61 Floor Const to STC 54 7 lb. ft. |
Riverbank Acoustical Labs |
| Light Reflectance |
ASTM C523-68 | .75 | Riverbank Acoustical Labs |
| Surface
Burning Characteristics |
ASTM E84-84 ANSI 2.5, NFPA 255, UBC 42-1, UL 723 |
Flame Spread
0 Fuel Contributed 0 Smoke Developed 0 |
Commercial Testing Co. |
| Fungus | ASTM C738 UMB 80 |
Passed | Commercial Testing Co. |
| R-Value Dry Density |
ASTM C518-76 ASTM E605 |
R 3.8 per
inch dependant on density |
Commercial Testing Co. |
| Thermal Conductivity |
ASTM C518-76 | K = .26 | Commercial Testing Co. |
| Moisture Absorption |
ASTM C739 UMB 80 |
7.0% by weight | Commercial Testing Co. |
| Corrosive | ASTM 739 UMB 80 |
Non corrosive on copper, steel, aluminum |
Commercial Testing Co. |
| Corrosiveness | ASTM E937 | Non corrosive on bare steel, galvanized steel, shop coated steel |
United
States Testing |
| Odor Emission | ASTM C739 UMB 80 |
Passed | Commercial Testing Co. |
| Bond Strength | ASTM E736 UMB 80 |
Greater that 357 lbs. ft. |
Commercial Testing Co. |
| Bond Deflection | ASTM E759 | No delamination No cracking |
Commercial Testing Co. |
| Air Erosion | ASTM E859 UMB 80 |
0.025 g. ft. | Commercial Testing Co. |
| Combustibility | ASTM E136 | Non combustible |
Commercial Testing Co. |

If you rely on anything less than American Fireproofing, you are playing with fire!